Skip to main content

Unlocking the potential of NMR spectroscopy for precise and efficient quantification of microplastics

Abstract

Precise, fast, and reliable identification and quantification of microplastic contamination are essential for determining their environmental concentrations for risk assessments. This study investigates the use of nuclear magnetic resonance (NMR) spectroscopy to quantify microplastics by analysing dilution series of polystyrene (PS), polyisoprene-cis (PI), polybutadiene-cis (PB), polylactic acid (PLA), polyvinyl chloride (PVC) and polyurethane (PU). Each polymer type was dissolved in a suitable solvent and an internal standard was utilized for quantification. Detection and quantification limits for each polymer type were established in two ways: (1) by using an equation based on proton signals and an internal standard with known concentration and (2) by using the LOQ based on the signal-to-noise ratio. Both data sets were compared and showed that using the internal standard (method 1) results in more accurate and lower concentration limits in the range of 0.2–8 µg mL−1 for all six polymer types, while the LOQ based on the SNR (method 2) gives consistently higher concentration limits (1–10 µg mL−1). The research shows the accuracy, efficacy, and reliability of quantitative NMR spectroscopy for polymer analysis in these concentration ranges compared to established quantifying methods, such as, PyGC/MS, FTIR, or Raman spectroscopy.

Introduction

Global plastics production has reached 400.3 million tons per year [1], leading to widespread use of plastic items in modern life [1,2,3]. Plastics are a diverse group of materials, including commonly produced polymers like polypropylene (PP), polyethylene (PE), polyvinyl chloride (PVC), polystyrene (PS), polyester (PET), polyurethane (PU) etc [1]. Microplastics (MPs, 1 μm to 5 mm [3, 4]) and nanoplastics (NPs, < 1 μm [5,6,7,8]), have become a topic of great concern regarding to human-health and environmental risk [2, 9]. Primary microplastics are produced as micro-sized particles [10], while secondary microplastics are generated from the breakdown of larger plastic [11,12,13,14]. The omnipresence, small size, ingestion, uptake and translocation of MPs into tissues have made them a major environmental issue [4, 11,12,13], requiring further research to clarify the evidence for their toxicity [15]. Risk assessments require quantification of the substances in question and determination of dose-effects [16].

Knowledge of exposure levels and hazards form the basis of risk assessments [17, 18]. Rapid, reliable and cost-efficient quantification of MP concentrations in all sorts of matrices are thus needed for better risk assessments. Currently, there are several methods used to identify, qualify, and quantify MPs in environmental samples [19, 20]. These methods include optical methods such as scanning electron microscopy (SEM), Fourier-transform infrared spectroscopy (FTIR), and Raman spectroscopy which are mainly used to qualitatively identify the type of polymer [20]. SEM provides high-resolution images of MP surface details up to 0.5 nm and therefore, can be used to analyse the weathering process of MPs in natural environments [21]. Besides the disadvantage of being an expensive and time consuming method, SEM is restricted in differentiating between plastics and other particles which leads to a high potential for misclassification of polymer types [22]. The perhaps best suited and most used method to identify plastic items > 11.3 μm, is FTIR [2, 23]. In comparison to µ-FTIR, Raman spectroscopy is more suitable to identify small MPs (> 1 μm) and deliver their chemical and structural characteristics [24]. Both methods, FTIR and Raman spectroscopy are non-destructive and determine the dimension of particles by visual images, which enables the quantification of MPs based on the particle dimensions and the density of the polymer in question [25]. Nevertheless, this quantification of MPs is not practical due to both optical methods in terms of being time-consuming, and often require intense and expensive sample preparation [26]. Due to inconsistent information on the abundance of microplastic particles given by different studies, comparability of results remain challenging [27,28,29]. Consequently, there is a need for more efficient and accurate methods for quantifying MP concentrations in environmental samples. Recently, thermoanalytical methods such as thermal desorption gas chromatography-mass spectrometry (TDS-GC-/MS) and pyrolysis gas chromatography-mass spectroscopy (PyGC/MS) have been developed to qualitatively and quantitatively detect microplastics by their characteristic decomposition products [25, 30, 31]. These methods have disadvantages such as time-consuming and expensive sample preparations and having limitations such as destroying the sample, hence providing no information about size and shape of the MP particles [30]. To summarize, most of the current best-practice methods are expensive, time-consuming and, due to the high costs per sample, it has become customary to perform only one replicate analysis [26].

Recent research highlights that there is a significant demand for further development of both qualitive and quantitative analysis methods due to the insufficient knowledge of MP concentrations in a range of environmental matrices. Over the last 10 years, quantitative nuclear magnetic resonance (qNMR) spectroscopy has gained popularity as a method for quantitatively detecting and analysing various substances [32, 33], including microplastic particles [34,35,36,37]. qNMR has several advantages including being fast and cost-effective, size-independent, sensitive, precise and simple to perform [32, 33]. One potential limitation of qNMR for analysing microplastic particles is that the particles must be dissolved in a suitable solvent [38], which leads to a loss of information on particle size, colour and shape. Additionally, high-resistant polymer types like PP and PE can only be dissolved at high temperatures [39,40,41] which currently causes a restriction for the use of qNMR for now. A limiting factor for qNMR is the limit of detection (LOD) and limit of quantification (LOQ). LOD refers to the minimum concentration of an analyte in a sample that can be identified but not necessarily quantified under the specified test conditions. In contrast, LOQ is defined as the lowest concentration of an analyte in a sample that can be reliably quantified [42, 43]. For future use of qNMR in MP quantification it is important to determine these limitations for each polymer type, which will determine the suitable areas of use for the rapid and inexpensive qNMR method.

Recent studies reported the validation of NMR acquisition of single polymers at different concentration levels in environmental samples [34,35,36,37]. In contrast, this study focuses on the detection and quantification of NMR spectroscopy for various polymer types by using standard qNMR parametric settings to ensure equality throughout different polymer types, aiming for the same precision and accuracy for all polymers. To our knowledge, qNMR spectroscopy has not been tested and optimized to reach the most accurate and lowest concentration limits possible for a wider range of polymer types. This study compares two different approaches to determine the concentration limits of the pure polymers PS, PLA, PVC, PU, PI and PB by comparing two methods: (1) using the internal standard with known concentration and the specific proton signals of each polymer type and (2) by using the same output data to determine the concentration limits based on the signal-to-noise ratio (SNR).

Materials and methods

Microplastic particles

Microplastic particles were utilized as model particles for detection and quantification by qNMR: PS, PLA, PU beads with a size distribution of 3–5 mm were purchased from GoodFellow Cambridge Ltd., England; PVC powder with a size distribution of < 50 μm and a purity of > 99.7% was acquired from Werth-Metall, Germany; the natural rubber Polyisoprene-cis (PI) and the synthetic rubber Polybutadiene-cis (PB) were purchased from Sigma Aldrich. Although commercially available particles were utilized as polymer particles, they were deliberately not established standards.

Sample preparation

Deuterated chloroform (CDCl3, 99.8 atom % D) from Sigma-Aldrich was used for dissolving PS, PI, PB and PLA. For dissolving PVC and PU, deuterated tetrahydrofuran (THF-d8, ≥ 99.5 atom % D) purchased by Sigma-Aldrich and VWR International, LLC. was used. All polymer types in their corresponding solvents were dissolved at room temperature. A stock solution of the different polymer types was used to prepare a dilution series of varying concentration levels. The dilution series of PS and PVC were prepared with concentrations in the range of 0.1 to 100 µg mL−1 and PB, PLA, PI and PU with concentrations in the range of 0.01 to 100 µg mL−1. All dilution series were represented with one replicate of each concentration level. The highest concentration level served as a reference. In order to quantify the amount of polymers in the sample, an internal standard of dimethyl sulfone (DMSO2) purchased by TraceCERT®, Sigma-Aldrich with a known concentration was added to each polymer sample. To conduct NMR measurements, a volume of 600 µL of the sample solution was transferred into NMR tubes with a diameter of 5 mm (Bruker BioSpin, 4′′ NMR tubes) and subsequently analysed.

1H qNMR – quantitative analysis

All NMR experiments were performed using a Bruker Ascend 600 MHz spectrometer with an AVANCE NEO console and a QCI-P CryoProbe™. Measurements were performed at 298 K. In qNMR measurements, the acquisition parameters for all MP particles were standardized, with receiver gain and pulse width calibrated automatically for each sample. The spectral width was set at 29.76 ppm, number of scans at 8, spectral size at 262,144 points, acquisition time at 3.67 s, and delay at 60 s for each sample.

For illustrating the obtained 1H NMR spectra, data were imported into the NMR software program MestReNova (v14.2.0), whereas the qNMR spectra for quantification were imported into the NMR software program TopSpin from Bruker (Version 4.1.3.). For all qNMR data a phase correction and baseline correction were performed manually. All data had a line broadening of 0.1 Hz. For each polymer type, a consistent ppm range was manually integrated in all samples. The integration of the signal areas correlates to the proton atoms and consequently to the concentration of the analyte in the solution. For quantitative assessment, special attention must be taken when integrating the signal regions of interest. To reduce potential measurement or integration errors, the internal standard method was utilized for all quantitative determinations [33]. The proton signal of DMSO2 functioned as internal standard in all polymer samples. In order to use DMSO2 as internal standard, it must be ensured that the same concentration is added to each polymer sample and that the concentration is chosen to be in the same intensity range as the deuterated solvents. The concentration of polymers in their corresponding solvents was calculated as follows:

$$\:{C}_{u}={C}_{r}\frac{{A}_{u}}{{A}_{r}}\frac{{n}_{r}}{{n}_{u}}$$
(1)

\(\:{A}_{r}\): integral of the proton of the internal standard with known concentration

\(\:{A}_{u}\): integral of the proton of the polymer sample with unknown concentration

\(\:{C}_{r}\): concentration of the internal standard with known concentration

\(\:{C}_{u}\): concentration of the polymer sample with unknown concentration

\(\:{n}_{r}\): number of atoms of the proton of the internal standard with known concentration

\(\:{n}_{u}\): number of atoms of the proton of the polymer sample with unknown concentration

Calculations and statistical analyses

For the first method, all data were analysed using RStudio (Version 4.1.3). The measured concentration of each polymer type (calculated by Eq. 1) was plotted against the nominal concentration. ANOVA (analysis of variances) was used to calculate variability within the regression models and for significance tests. Therefore, the significance level was set to p < 0.05 and F-statistic tests were analysed. Additionally, the confidence interval was set to 0.95. The linearity was established by determining the slope, intercept, and the coefficient of determination (R2). Moreover, the precision of each polymer concentration level in the dilution series and the mean absolute percentage error (MAPE) of the dilution series compared to the nominal values were calculated for each polymer type (Eq. 2).

$$\:MAPE\:\left[\%\right]=\:\left(\left(\frac{1}{n}\right)\sum\:_{t=1}^{n}\left|\frac{{A}_{t}-{M}_{t}}{{A}_{t}}\right|\right)*100$$
(2)

\(n\):polymer sample size

\(\:{A}_{t}\): nominal concentration of the polymer sample

\(\:{M}_{t}\): measured concentration of the polymer sample

For the second method, we used the signal-to-noise ratio (SNR). The limit of detection (LOD) defined as a SNR of 2:1 or 3:1 and limit of quantification (LOQ) defined as a SNR of 10:1, as previously determined [43, 44].

Prevention of contamination and quality control

To prevent the samples from being contaminated with microplastic from airborne particles, glassware and other plastic free equipment underwent a thorough washing process using water, acetone, and distilled water. Glass flasks were dried for 24 h at 60 °C before use and properly sealed with a lid or aluminium foil after cooling off. NMR tubes were dried for 30 min at 60 °C or overnight at room temperature in a closed laboratory oven. Furthermore, precautions were taken to ensure that lab coats made of pure cotton were worn and closed during sample handling to prevent contamination by clothing polymer fibers. In addition, gloves were worn and changed regularly to prevent cross contamination. All procedures possible were performed under a fume hood. The work surface under the fume hood was cleaned with 95% ethanol and dried with nonabrasive tissues before and after the use and between polymer types [45, 46]. Moreover, the sample tubes were immediately sealed during the dissolution to avoid evaporation of the volatile solvents. As procedural blanks, 1H NMR and qNMR spectra of pure CDCl3 and THF-d8 from bottles and ampules without polymer added, who were also exposed to the fume hood in the same manner as the diluted samples, were acquired.

Results and discussion

Sample preparation and investigation of suitable deuterated solvents

Not all polymers will dissolve in the same solvent. Several suitable solvents were tested, and six polymer types and two solvents were chosen for further method comparison. These were PS, PVC and PU which are among the most abundant polymers produced today (23.2% of the global plastic production [1]). Polyisoprene-cis (PI – “natural rubber”) and polybudatiene-cis (PB – “synthetic rubber”) that are mainly used for tire, footwear and latex production due to their highly elastic properties were chosen to represent rubber. Recently, PI and PB have gained increased attention and interest because of new studies on their presence in environmental samples, as well as their behaviour in the environment and possible harmful effects [47, 48]. PLA is a bioplastic that originated from renewable biomass sources. Due to its similar characteristics as the most abundant plastics PP, PE, and PS [49, 50], PLA has gained more attention in the last few years [51]. However, PP and PE are the most abundant polymers [39,40,41], but due to their low solubility under normal laboratory conditions, they were not used in this study. Hence, using qNMR for quantification of PE and PP will need further studies.

Conducting quantitative analysis by using NMR spectroscopy, a complete dissolution of the polymer in a deuterated solvent that meets specific criteria is necessary. These requirements include selecting a deuterated solvent whose chemical shift signal differs significantly from those of the polymer to allow for the effective utilization of proton signals as internal standards, and thus, facilitate accurate quantification. In addition, it is vital to ensure that the polymers are fully solubilized rather than simply “swollen”, as this renders measurement unfeasible [52]. We used deuterated chloroform (CDCl3) and deuterated tetrahydrofuran (THF-d8) as solvents [34, 36, 38, 53,54,55]. Deuterated chloroform was found to be a suitable solvent for PS, PB, PI and PLA with its proton signal at 7.26 ppm. The more expensive deuterated tetrahydrofuran with its proton signals at 3.58 ppm and 1.73 ppm was also a suitable solvent for PVC, PU and again PS. The dilution series of PS were only performed with CDCl3 to reduce costs.

Contamination control

As procedural blanks, samples of each solvent were taken from ampules and glass bottles and run without the addition of a polymer. The 1H NMR spectra showed that both solvents from both sources contained, besides the water (H2O) signals at 1.56 ppm in CDCl3 and 2.50 ppm in THF-d8, several other contaminations especially in the lower ppm range [56]. These impurities were considered while observing possible signal overlays. Since all handlings were performed under a fume hood, external contaminations have been considered. As the procedural blanks were exposed to the fume hood, any contamination that might have entered the sample in the fume hood, was either not dissolvable in the corresponding solvent or too little to detect with the qNMR.

Qualitative analysis by 1H-NMR

The standard 1H NMR spectra of PS, PLA, PI and PB in CDCl3 are presented in Fig. 1, and the 1H NMR spectra of PU and PVC in THF-d8 are shown in Fig. 2. A dissolution of the polymer particles was performed before conducting the measurements. The 1H NMR spectrum of PS showed two signal ranges from 7.20 to 6.20 ppm and 2.30 to 1.10 ppm (Fig. 1A). The first range was assigned to the protons of the aromatic ring (Ha, Hb), and the second range to the protons of the CH2-group (Hc) and CH-group (Hd) [57]. PLA (Fig. 1B) was assigned to two proton signals. The first signal in the range of 5.20 to 5.12 ppm (Ha) was assigned to the protons of the CH-group and the second signal in the range of 1.61 to 1.56 ppm (Hb) to the protons of the CH3-group [38]. Two signals of PB were found (Fig. 1C). The signal at 5.38 ppm (Ha) corresponded to the protons of the two CH-groups along the double bond and 2.09 ppm (Hb) was assigned to the protons of the two CH2-groups [38]. PI was assigned to three signals (Fig. 1D). The signal at 5.12 ppm (Ha) corresponded to the protons of the CH-group along the double bond, whereas the signal at 2.04 ppm (Hb) represented the protons of the two CH2-groups and the protons of the CH3-group were shown in the signal at 1.68 ppm (Hc) [58].

Fig. 1
figure 1

1H NMR spectrum and structural formula of (A) polystyrene (PS), (B) polylactic acid (PLA), (C) polybutadiene-cis (PB) and (D) polyisoprene-cis (PI) in CDCl3 with a nominal concentration of 1 mg mL−1 and DMSO2 as internal standard. The spectra were acquired on a 600 MHz instrument

The 1H NMR spectrum of PVC showed two signal ranges from 4.70 to 4.25 ppm and 2.44 to 2.00 ppm (Fig. 2A). Both signal ranges were assigned to a CH-group (Ha, Hb) [34]. PU showed six signals (Fig. 2B). The proton signals of doublets in the range of 8.67 to 8.47 ppm (Ha, He), 7.07 to 6.98 ppm (Hc) and 4.15 to 4.95 ppm (Hf) were assigned to the protons of the NH-group, the aromatic rings and a CH2-group, respectively. A proton signal was found in the range of 7.43 to 7.29 ppm (Hb) and belongs to the protons of the aromatic rings. The proton signal at 3.82 ppm (Hd) was assigned to the CH2-group between the aromatic rings and the proton signal at 3.36 ppm (Hg) belongs to a CH2-group [59].

Fig. 2
figure 2

1H NMR spectrum and structural formula of (A) polyvinyl chloride (PVC) and (B) polyurethane (PU) in THF-d8 with a nominal concentration of 1 mg mL-1 and DMSO2 as internal standard. The spectra were acquired on a 600 MHz instrument

Calculations and statistical analyses

To validate the suitability of NMR spectroscopy in quantitative analysis of polymer concentrations, the measured concentration limits according to Eq. 1 and parameters such as MAPE, accuracy and linearity were determined (method 1). For comparison with the concentration in method 1, the LOD and LOQ were calculated based on the SNR (method 2).

Method 1

In method 1, linear regressions were used to determine the linearity between nominal concentrations and measured concentrations based on the integrated signals for the dilution series for each polymer (Figs. 3, 4 and 5). The nominal concentration of each polymer in the corresponding solvent was plotted against the measured concentration in microgram per millilitre (see Eq. 1), along with upper and lower confidence limits of 0.95 and coefficient of determination (R2) for each regression line. The method can be considered linear with a R2 of > 0.99 [60]. Data points that reduced R2 values of the regression lines were omitted. This was most often the case for the low concentrations of each polymer type which then affected the lowest concentration that could be considered accurately quantified (see Supplementary Material). The chosen proton signal regions of the polymer types of PS, PB, PI, PLA and PU showed R2 > 0.9914. Only PVC had a slightly lower R2 of 0.9879. The application of MAPE (mean absolute percentage error) as a loss function for regression analysis is viable from both practical and theoretical perspectives, as it can be demonstrated that an optimal model exists and the empirical risk minimization is consistent [61]. The MAPE was also used in utilizing the robustness of a regression model and as regression quality measure [62]. The MAPE values of the different polymer types ranged between 1.35% and 17.17%. Additionally, ANOVA showed a significance level of p < 0.05 and a large F-statistic value for the statistical analysis of each polymer type which concluded a significant relationship between the measured concentration limits and the nominal concentrations.

Method 2

The determination of LOD and LOQ is based on the SNR, whereas a SNR of 3:1 or 2:1 is considered to be the LOD and a SNR of 10:1 as LOQ [43, 44]. Therefore, the SNR of all polymer concentration levels were established and LOD and LOQ compared with the results from method 1.

Detection limit by qNMR quantification

The measurement and evaluation of spectra in quantitative NMR spectroscopy require a different set of considerations compared to those utilized in qualitative NMR spectroscopy [32, 33]. However, the importance of precision and accuracy must be emphasized when using phase correction, baseline correction, and integration for polymers in different concentration levels. The quantification of each polymer type at different nominal concentrations was done by using the signal intensities specific for that polymer and the internal standard DMSO2 according to Eq. 1. Due to overlaps and impurities in some polymer signals, only specific protons were used to quantify the polymer concentration.

The linear regression of PS-Ha,Hb in CDCl3 and PVC-Ha in THF-d8 with concentration rages of 0–100 µg mL−1 and PLA-Ha in CDCl3 with a concentration rage of 0–10 µg mL−1, including their corresponding R2 are given in Fig. 3.

Table 1 Quantification limits of the different polymer types by method 1 and method 2. The measured concentration limits [µg mL−1], the accuracy [%], the MAPE per polymer type [%] (method 1) and the determination of limit (LOD) and quantification (LOQ) [µg mL−1] (method 2) are given

Polystyrene

Results for PS-Ha,Hb using method 1 showed a concentration limit of 4 µg mL−1 with an R2 of 0.9966 (Table 1). Based on method 2, the LOQ was > 10 µg mL−1 and the LOD was 2 µg mL−1. The proton NMR spectrum of pure CDCl3 observed the solvents 13C-satellites at 7.43 ppm and 7.08 ppm [63]. The right satellite of CDCl3 collided with the PS region of the aromatic ring. However, at higher concentrations the overlap of the signals will not be evident, but it will be present at lower concentrations which will lead to higher SNR in the different concentration levels of PS. Therefore, the SNR of PS was determined by choosing the best suitable PS signal without the 13C satellite of CDCl3 to determine the corresponding LOD and LOQ values.

Peez et al. [35] and Peez & Imhof [34], both determined LOQ and LOD for PS which was much higher than the LOQ and LOD of PS within this study. Papini et al. [37] reported a quantification in multiphasic matrices of marine sediments with ~ 27 ± 16 µg L−1 of PS and detected a LOQ of 1.4 µg and LOD of 0.6 µg based on the proton region of two protons of the aromatic ring by using NMR measurements. In comparison, Peez et al. [35] reported a LOQ of 77 µg mL−1 and LOD of 19 µg mL−1 for PS in a concentration range of 30–930 µg mL−1 based on DIN32645. In their follow-up study in 2020, they referred to the same PS values from 2019 and stated a LOQ of 92 µg mL−1 and LOD of 28 µg mL−1 based on the SNR, anyhow this means a LOQ of above 77 µg mL−1. In addition, Peez et al. [35] determined a possible overlap of the signals of CDCl3 and the aromatic ring of PS in case to use the solvent for quantitative analysis. Compared to this study’s observation, there is an overlap which was considered during the determination of LOD and LOQ based on the SNR. In contrast, the PyGC/MS method demonstrated a LOD of less than 1 µg for PS particles, as determined by SNR [31].

Polyvinyl chloride

The observed concentration limit using method 1 for PVC-Ha was 8 µg mL−1 with R2 of 0.9876 (Table 1). Method 2 on the other hand gave a higher LOQ > 10 µg mL−1 and a LOD of 1 µg mL−1. In previous studies, Peez and Imhof [34] determined a LOQ of 281 µg ml−1 and a LOD of 84 µg mL−1 for PVC in a concentration range of 0.28–1.40 mg mL−1 based on the SNR [43]. In comparison, the PyGC/MS method showed a LOD of < 2.7 µg for PVC particles, based on the SNR [31].

Polylactic acid

For PLA-Ha the concentration limit using method 1 was 0.2 µg mL−1 with R2 of 0.9934 (Table 1), while method 2 gave a tenfold higher LOQ of > 2 µg mL−1 and a LOD of 0.6 µg ml−1. Although PLA is an environmental relevant polymer, it has not been quantified with qNMR so far, and therefore, there are some difficulties in comparing this study’s findings to previous studies. However, its increasing attention due to the enormous use in packaging, PLA needs to be quantified fast and accurate.

Fig. 3
figure 3

Linear Regression for (A) PS-Ha,Hb in CDCl3 and (B) PVC-Ha in THF-d8 with concentration rages of 0–100 µg mL−1 and (C) PLA-Ha in CDCl3 with a concentration range of 0–10 µg mL−1. All polymer types include an internal standard of DMSO2 and are represented with a confidence interval (0.95). The nominal concentration is plotted against the measured concentration (calculated by Eq. 1)

Polybutadiene and polyisoprene - rubbers

The two rubber types of polybutadiene-cis (PB) and polyisoprene-cis (PI) with two of their proton signals each and their corresponding R2 are shown in Fig. 4. Both polymer types were dissolved in CDCl3. The linear regression is shown in a concentration rage of 0–10 µg mL−1 for each polymer signal. The concentration limit using method 1 for PB-Ha was 0.8 µg mL−1 with R2 of 0.9950 (Table 1). For method 2 the LOQ was similar, with an LOQ of 1 µg mL−1 and LOD of 0.2 µg mL−1. The second signal, PB-Hb, had its concentration limit using method 1 at 0.4 µg mL−1 with R2 of 0.9957 (Table 1), while method 2 gave a similar LOQ of 0.4–0.6 µg mL−1 and a LOD of 0.04 µg mL−1. Similarly, the concentration limit of PI-Ha using method 1 was 2 µg mL−1 with R2 of 0.9975 (Table 1), which was close to the result using method 2, with a LOQ of 2 µg mL−1 and a LOD of 0.8 µg mL−1. For the second signal of PI, the results were also similar where the concentration limit of PI-Hb using method 1 was 0.6 µg mL−1 with R2 of 0.9938 (Table 1) and for method 2, the LOQ was 0.8–1 µg mL−1 and LOD was below 0.01 µg mL−1.

Fig. 4
figure 4

Linear Regression for (A) PB-Ha, (B) PB-Hb, (C) PI-Ha and (D) PI-Hb in CDCl3 with concentration rages of 0–10 µg mL−1. All microplastic types include an internal standard of DMSO2 and are represented with a confidence interval (0.95). Plotted is the nominal concentration against the measured concentration (calculated by Eq. 1)

However, as qNMR has not been used to quantify these two types of rubber thus far, there are challenges in comparing the findings of this study to previous research. Nonetheless, due to their widespread use in tire production [47], it is essential to quickly and accurately quantify PB and PI as they continue to attract increasing attention.

Polyurethane

The linear regression of the three signals of PU in THF-d8 with concentration ranges of 0–10 µg mL−1 and their corresponding R2 are given in Fig. 5. The concentration limit using method 1 of PU-Ha,He was 4 µg mL−1 with R2 of 0.9914 (Table 1). Method 2 gave a higher LOQ of > 10 µg mL−1 and LOD of 6 µg mL−1. The second signal, PU-Hb, had its concentration limit using method 1 of 2 µg mL−1 with R2 of 0.9987 (Table 1), while method 2 gave a fivefold higher LOQ of > 10 µg mL−1 and a LOD of 2 mL−1. The concentration limit of the third signal, PU-Hc, using method 1 was 1 µg mL−1 with R2 of 0.9992 (Table 1), while method 2 gave a sixfold higher LOQ of 6 µg mL1 and a LOD of 1 µg mL−1. PU is one of the most prevalent polymers due to its widespread use [64]. To date, qNMR has not been used for its quantification. Therefore, comparing the results of this study with previous research poses certain difficulties. Nonetheless, fast and accurate quantification of PU could offer an advantage for future studies.

Fig. 5
figure 5

Linear Regression for (A) PU-Ha,He, (B) PU-Hb and (C) PU-Hb in THF-d8 with concentration rages of 0–10 µg mL−1. All microplastic types include an internal standard of DMSO2 and are represented with a confidence interval (0.95). Plotted is the nominal concentration against the measured concentration (calculated by Eq. 1)

Uncertainty and accuracy in polymer quantification using qNMR

In total, previous research on quantifying and determining LOD and LOQ of different polymer types have been done with different methods. Peez et al. [35] calculated the LOD and LOQ according to the German standard DIN32465, Peez and Imhof [34] estimated the limits according to the SNR by Shrivastava and Gupta [43] and Papini et al. [37] used the SNR based on LOD being 2:1 and LOQ being 5:1 and having the SNR dependent on the MP concentration. In addition, Papini et al. [37] acquired their data with a line broadening of 5 Hz which makes it difficult to directly compare the LOD and LOQ of this study with a line broadening of 0.1 Hz. Data that is acquired with a higher line broadening improves the SNR but is insufficient for quantification. Moreover, the dependence on the MP concentration indicates the assumption of a stable SNR.

In fact, using the SNR comes with a higher uncertainty. The quantitative imprecision of qNMR is documented to be less than 2.0%, which is an acceptable threshold for precise and accurate quantification [32, 65]. The quantification with LOQ with a SNR of 10:1 would have approximately a 5% standard deviation. The validation protocol by Malz and Jancke [65], which is based on the test of robustness, linearity, accuracy, selectivity and specificity of qNMR measurements, revealed that with a 95% confidence interval, the uncertainty of the qNMR measurements is 1.5%.

Recent research used a calibration curve to estimate the concentration [34,35,36,37]. The calibration curve method in qNMR involves preparing standard solutions with known concentrations of the analyte, recording instrument response, and plotting signal intensity against nominal analyte concentration. An equation for the calibration curve is developed by linear regression and used to compute unknown solution concentrations. This technique is useful for quantitative estimation of small molecules or simple mixtures [32]. However, there are challenges associated with using the calibration curve method in qNMR. These include time-consuming establishment of standard curves, require larger sample volumes, and difficulties in maintaining consistent experimental parameters. Especially for expected low concentration, such as in the case of MPs in environmental samples and different organic matrices, the use of the calibration curve is not suitable [33].

Method 2 vs. method 1

In general, quantitative analysis using qNMR relies on the proportional correlation between the integrated signal area and the quantity of resonant nuclei [32, 33, 66]. Founded on this, by including an internal standard with a known concentration and considering the number of protons of the specific region of interest, the measured concentration limits of each polymer types based on Eq. 1 are more accurate than the LOQ based on the SNR. In summary, the concentration limits for quantification of the six polymer types are in the range of 0.2–8 µg mL−1 using method 1. Method 1 consistently shows lower concentration limits than method 2 for all polymers except for the second signal of polybutadiene-cis (PB-Hb) and the first signal of polyisoprene-cis (PI-Ha). The difference can be as much as tenfold higher for method 2 than method 1. Moreover, the concentration limits using method 1 are supported by accuracy and MAPE results. Most LOQ values are either close to the measured concentration limits of the different polymer types or way above it which is also due to the restricted dilution series and therefore, missing concentration levels. Using the SNR shows that the LOQ for most polymer types are not as precise as the measured concentration limits.

Sample processing and limitations of NMR

Overall, for qNMR to be effectively applied, it is essential for the detection and quantification limits to align with environmentally significant concentrations. This study shows that qNMR proves to be an effective instrument for quantitative analyses down to 0.2 µg mL−1 for a selection of environmentally relevant polymers. While these concentration limits may render qNMR unsuitable for monitoring very low concentrations in small samples, it may be viable for monitoring environmental samples like sediments and soil with high concentrations or plenty of available sample material such as water. Water samples with large volumes can easily be concentrated by filtration and sediment samples where volumes over 1 kg can be used for extraction by density separation using the Munich Plastic Sediment Separator (MPSS) [67, 68].

However, before the method can be used for analysing environmental mixed samples, a solvent for common polymer types such as PP and PE must developed further and a good strategy of how to treat one sample for different polymers since they require different solvents. Moreover, a diversity of organic compounds and different polymers present in environmental samples may lead to overlapping signals, making spectral interpretation challenging. Therefore, like FTIR, PyGC/MS and Raman spectroscopy, thorough sample preparations such as extraction by density separation, filtration, and purification by oxidizing agents or enzymatic digestion may need to be performed. Hence, controlled studies comparing pristine polymer mixtures and realistic environmental samples containing aged or weathered polymers are necessary. However, with the low cost of NMR, method development may be faster and cheaper than the currently used methods.

Quantification and concentration estimates

MP concentrations in literature are typically expressed as particle numbers found in environmental samples, but only recently have started to report a mass concentration as well, based on an estimated third dimension of the particle [23]. However, there is also a need for accurate polymer concentrations in environmental samples in terms of mass [69] in order to perform risk assessment and classify contamination levels. Studies on MP in soil revealed MP concentrations of 4.5 mg kg−1 including the most common polymer types that have been analysed by time-consuming methods like light microscope, FTIR, PyGC/MS, and Raman [70, 71]. The number of replicates and the number of sampling sites is often limited by the cost of processing and analyses using FTIR. Despite the expensive and time-consuming methods, the results often show a large variance across laboratories, and there is an urgent need for ring tests and harmonized methods and reporting units [28, 72, 73] before the quantitative results of FTIR may be considered reliable. Using NMR, the low costs of analyses are of benefit. Although parallels may be considered technical replicates and subsamples from an inhomogeneous extract of MPs, the low cost and short time running the qNMR analyses allows for a higher degree of certainty than a single analysed subsample can provide.

This study, however, shows that qNMR can be a good supplement and a method for rapid and reliable quantification of MPs in the medium to high concentration ranges of selected polymers. Limitations to the quantification of the most common polymers PE and PP can be overcome by developing new methods for their complete dissolution.

The utility of new and old methods

A combination of qNMR and non-destructive spectroscopic technique, such as FTIR or Raman, enables the analysis of both the size distribution and concentration of polymers in single samples. Although visual ques to the source of microplastics can be desired sometimes, there are now a number of environmental matrices where the occurrence of microplastics is expected, and where the particles are well known to be a range of different shapes and sizes, and where it has been known for some time that particles under 100 μm dominate [68, 74,75,76]. Since the presence of microplastics in the environment is no longer newsworthy, and the need for reliable monitoring-tools has been expressed for some time already. A rapid quantitative analysis that is sufficiently detailed to enable environmental classification of MP may be of higher interest than descriptions of the colour and shape of a small subsample of an inhomogeneous mixture. Further development of this method to quantify MPs in mixed environmental samples is therefore of the highest interest. Moreover, there are also relevant sample types, such as human tissue samples, where the need for detection of very low concentrations and knowledge of the particle size and shape is still of the essence and cannot be performed by qNMR. Such analyses must still be performed using FTIR or Raman.

Conclusion

In conclusion, this study demonstrates that qNMR spectroscopy provides a suitable way to quantify the concentration limits of polystyrene (PS), polyvinyl chloride (PVC), polyisoprene-cis (PI), polybutadiene-cis (PB), polylactic acid (PLA) and polyurethane (PU) in their corresponding solvents, in the range of 0.2–8 µg mL−1. All concentration limits were measured by using an internal standard with a known concentration, which proved more accurate and sensitive than determining the limit of quantification based on the signal-to-noise ratio (SNR). qNMR represents a fast, accurate, reliable and size-independent analysis for qualitative and quantitative measurements of selected polymers.

Availability of data and materials

No datasets were generated or analysed during the current study.

Abbreviations

PS:

Polystyrene

PI:

Polyisoprene-cis

PB:

Polybutadiene-cis

PLA:

Polylactic acid

PVC:

Polyvinyl chloride

PU:

Polyurethane

PET:

Polyester

PP:

Polypropylene

LD/HD-PE:

Polyethylene

MP:

Microplastic

NP:

Nanoplastic

SEM:

Scanning electron microscopy

FTIR:

Fourier-transform infrared spectroscopy

PyGC/MS:

Pyrolysis gas chromatography-mass spectrometry

TDS-GC-/MS:

Thermal desorption gas chromatography-mass spectrometry

qNMR:

Quantitative Nuclear Magnetic Resonance

LOQ:

Limit of Quantification

LOD:

Limit of Detection

CDCl3 :

Deuterated chloroform

THF-d8 :

Deuterated tetrahydrofuran

r.t.:

Room temperature

DMSO2 :

Dimethyl sulfone

1H NMR:

Proton nuclear magnetic resonance

SNR:

Signal-to-noise ratio

MAPE:

Mean absolute percentage error

MPSS:

Munich Plastic Sediment Separator

References

  1. Plastics Europe Plastics – the Fast Facts 2023. Plast. Eur. 2023.

  2. Lusher A. Microplastics in the Marine Environment: Distribution, Interactions and Effects. In: Bergmann M, Gutow L, Klages M (eds). Marine Anthropogenic Litter. Cham: Springer; 2015. https://doi.org/10.1007/978-3-319-16510-3_10.

  3. Andrady AL, Neal MA. Applications and societal benefits of plastics. Philos Trans R Soc B Biol Sci. 2009;364:1977–84. https://doi.org/10.1098/rstb.2008.0304.

    Article  CAS  Google Scholar 

  4. Arthur C, Bamford H, Baker J. The occurrence, effects and fate of small plastic debris in the oceans. In: Proceedings of the International Research Workshop on the Occurrence, Effects and Fate of Microplastic Marine Debris, Tacoma, WA, USA. 2008. p. 9–11.

  5. Chae Y, An Y-J. Effects of micro- and nanoplastics on aquatic ecosystems: current research trends and perspectives. Mar Pollut Bull. 2017;124:624–32. https://doi.org/10.1016/j.marpolbul.2017.01.070.

    Article  CAS  PubMed  Google Scholar 

  6. Cole M, Galloway TS. Ingestion of nanoplastics and microplastics by Pacific Oyster Larvae. Environ Sci Technol. 2015;49:14625–32. https://doi.org/10.1021/acs.est.5b04099.

    Article  CAS  PubMed  Google Scholar 

  7. Rist S, Baun A, Almeda R, Hartmann NB. Ingestion and effects of icro- and nanoplastics in Blue Mussel (Mytilus Edulis) Larvae. Mar Pollut Bull. 2019;140:423–30. https://doi.org/10.1016/j.marpolbul.2019.01.069.

    Article  CAS  PubMed  Google Scholar 

  8. GESAMP Proceedings of the GESAMP International Workshop on Assessing the Risks Associated with Plastics and Microplastics in the Marine Environment. GESAMP Reports and Studies. 2020;103:5–39.

  9. Noventa S, Boyles MSP, Seifert A, et al. Paradigms to assess the human health risks of nano- and microplastics. Micropl & Nanopl. 2021;1:9. https://doi.org/10.1186/s43591-021-00011-1.

  10. Boucher J, Billard G. The Mediterranean: mare plasticum. 2020.

  11. Barnes DKA, Galgani F, Thompson RC, Barlaz M. Accumulation and fragmentation of plastic debris in global environments. Philos Trans R Soc Lond B Biol Sci. 2009;364:1985–98. https://doi.org/10.1098/rstb.2008.0205.

    Article  CAS  PubMed  PubMed Central  Google Scholar 

  12. Browne MA, Dissanayake A, Galloway TS, Lowe DM, Thompson RC. Ingested microscopic plastic translocates to the circulatory system of the Mussel, Mytilus Edulis (L). Environ Sci Technol. 2008;42:5026–31. https://doi.org/10.1021/es800249a.

    Article  CAS  PubMed  Google Scholar 

  13. Andrady AL. Microplastics in the marine environment. Mar Pollut Bull. 2011;62:1596–605. https://doi.org/10.1016/j.marpolbul.2011.05.030.

    Article  CAS  PubMed  Google Scholar 

  14. O’Brine T, Thompson RC. Degradation of plastic carrier bags in the marine environment. Mar Pollut Bull. 2010;60:2279–83. https://doi.org/10.1016/j.marpolbul.2010.08.005.

    Article  CAS  PubMed  Google Scholar 

  15. Koelmans AA, Besseling E, Wegner A, Foekema EM. Plastic as a carrier of POPs to aquatic organisms: a model analysis. Environ Sci Technol. 2013;47:7812–20. https://doi.org/10.1021/es401169n.

    Article  CAS  PubMed  Google Scholar 

  16. Ogonowski M, Wagner M, Rogell B, Haave M, Lusher A. Microplastics could be marginally more hazardous than natural suspended solids – A meta-analysis. Ecotoxicol Environ Saf. 2023;264: 115406. https://doi.org/10.1016/j.ecoenv.2023.115406.

    Article  CAS  PubMed  Google Scholar 

  17. van Raamsdonk LWD, van der Zande M, Koelmans AA, Hoogenboom RLAP, Peters RJB, Groot MJ, Peijnenburg AACM, Weesepoel YJA. Current Insights into Monitoring, Bioaccumulation, and Potential Health Effects of Microplastics Present in the Food Chain. Foods. 2020;9:72. https://doi.org/10.3390/foods9010072.

  18. Koelmans AA, Redondo-Hasselerharm PE, Nor NHM, de Ruijter VN, Mintenig SM, Kooi M. Risk assessment of microplastic particles. Nat Rev Mater. 2022;7:138–52. https://doi.org/10.1038/s41578-021-00411-y.

    Article  Google Scholar 

  19. Löder MGJ, Gerdts G. Methodology Used for the Detection and Identification of Microplastics—A Critical Appraisal. In Marine Anthropogenic Litter; Bergmann, M., Gutow, L., Klages, M., Eds.; Springer International Publishing: Cham, 2015; pp. 201–227 ISBN 978-3-319-16510-3.

  20. Tirkey A, Upadhyay LSB. Microplastics: an overview on separation, identification and characterization of microplastics. Mar Pollut Bull. 2021;170:112604. https://doi.org/10.1016/j.marpolbul.2021.112604.

    Article  CAS  PubMed  Google Scholar 

  21. Silva AB, Bastos AS, Justino CIL, Da Costa JP, Duarte AC, Rocha-Santos TAP. Microplastics in the environment: challenges in analytical chemistry - a review. Anal Chim Acta. 2018;1017:1–19. https://doi.org/10.1016/j.aca.2018.02.043.

    Article  CAS  PubMed  Google Scholar 

  22. Shim WJ, Hong SH, Eo SE. Identification methods in microplastic analysis: a review. Anal Methods. 2017;9:1384–91. https://doi.org/10.1039/C6AY02558G.

    Article  CAS  Google Scholar 

  23. Primpke S, Wirth M, Lorenz C, Gerdts G. Reference database design for the automated analysis of microplastic samples based on Fourier Transform Infrared (FTIR) Spectroscopy. Anal Bioanal Chem. 2018;410:5131–41. https://doi.org/10.1007/s00216-018-1156-x.

    Article  CAS  PubMed  PubMed Central  Google Scholar 

  24. Cabernard L, Roscher L, Lorenz C, Gerdts G, Primpke S. Comparison of raman and fourier transform infrared spectroscopy for the quantification of microplastics in the aquatic environment. Environ Sci Technol. 2018;52:13279–88. https://doi.org/10.1021/acs.est.8b03438.

    Article  CAS  PubMed  Google Scholar 

  25. Dümichen E, Barthel A-K, Braun U, Bannick CG, Brand K, Jekel M, Senz R. Analysis of polyethylene microplastics in environmental samples, using a thermal decomposition method. Water Res. 2015;85:451–7. https://doi.org/10.1016/j.watres.2015.09.002.

    Article  CAS  PubMed  Google Scholar 

  26. Huppertsberg S, Knepper TP. Instrumental analysis of icroplastics—benefits and challenges. Anal Bioanal Chem. 2018;410:6343–52. https://doi.org/10.1007/s00216-018-1210-8.

    Article  CAS  PubMed  Google Scholar 

  27. Bavel B. Lusher, A.L.; Consolaro, C.; Hjelset, S.; Singdahl-Larsen, C.; Buenaventura, N.T.; Röhler, L.; Pakhomova, S.; Lund, E.; Eidsvoll, D.;. Microplastics in Norwegian Coastal Areas, Rivers, Lakes and Air (MIKRONOR1); Norsk institutt for vannforskning, 2022. NIVA 7811-2023, p. 54. ISBN 978-82-577-7547-6.

  28. Hidalgo-Ruz V, Gutow L, Thompson RC, Thiel M. Microplastics in the marine environment: a review of the methods used for identification and quantification. Environ Sci Technol. 2012;46:3060–75. https://doi.org/10.1021/es2031505.

    Article  CAS  PubMed  Google Scholar 

  29. Primpke S, Cross RK, Mintenig SM, Simon M, Vianello A, Gerdts G, Vollertsen J. Toward the systematic identification of microplastics in the environment: evaluation of a new independent software tool (siMPle) for spectroscopic analysis. Appl Spectrosc. 2020;74:1127–38. https://doi.org/10.1177/0003702820917760.

    Article  CAS  PubMed  PubMed Central  Google Scholar 

  30. Dümichen E, Eisentraut P, Bannick CG, Barthel A-K, Senz R, Braun U. Fast identification of microplastics in complex environmental samples by a thermal degradation method. Chemosphere. 2017;174:572–84. https://doi.org/10.1016/j.chemosphere.2017.02.010.

    Article  CAS  PubMed  Google Scholar 

  31. Fischer M, Scholz-Böttcher BM. Simultaneous trace identification and quantification of common types of microplastics in environmental samples by pyrolysis-gas chromatography–mass spectrometry. Environ Sci Technol. 2017;51:5052–60. https://doi.org/10.1021/acs.est.6b06362.

    Article  CAS  PubMed  Google Scholar 

  32. Bharti SK, Roy R. Quantitative 1H NMR spectroscopy. TrAC Trends Anal Chem. 2012;35:5–26. https://doi.org/10.1016/j.trac.2012.02.007.

    Article  CAS  Google Scholar 

  33. Pauli GF, Jaki BU, Lankin DC. Quantitative 1 H NMR: development and potential of a method for Natural products Analysis. J Nat Prod. 2005;68:133–49. https://doi.org/10.1021/np0497301.

    Article  CAS  PubMed  Google Scholar 

  34. Peez N, Imhof W. Quantitative 1 H-NMR spectroscopy as an efficient method for identification and quantification of PVC, ABS and PA microparticles. Analyst. 2020;145:5363–71. https://doi.org/10.1039/D0AN00879F.

    Article  CAS  PubMed  Google Scholar 

  35. Peez N, Becker J, Ehlers SM, Fritz M, Fischer CB, Koop JHE, Winkelmann C, Imhof W. Quantitative analysis of PET microplastics in environmental model samples using quantitative 1H-NMR spectroscopy: validation of an optimized and consistent sample clean-up ethod. Anal Bioanal Chem. 2019;411:7409–18. https://doi.org/10.1007/s00216-019-02089-2.

    Article  CAS  PubMed  Google Scholar 

  36. Peez N, Janiska M-C, Imhof W. The first application of quantitative 1H NMR spectroscopy as a simple and fast method of identification and quantification of microplastic particles (PE, PET, and PS). Anal Bioanal Chem. 2019;411:823–33. https://doi.org/10.1007/s00216-018-1510-z.

    Article  CAS  PubMed  Google Scholar 

  37. Papini G, Petrella G, Cicero DO, Boglione C, Rakaj A. Identification and quantification of polystyrene microplastics in marine sediments facing a river mouth through NMR spectroscopy. Mar Pollut Bull. 2024;198: 115784. https://doi.org/10.1016/j.marpolbul.2023.115784.

    Article  CAS  PubMed  Google Scholar 

  38. Brandolini AJ, Hills DD. NMR Spectra of Polymers and Polymer Additives. CRC Press; 2000. p. 23–117. ISBN 978-1-4822-9342-5.

  39. Achilias DS, Roupakias C, Megalokonomos P, Lappas AA, Antonakou ΕV. Chemical recycling of plastic wastes made from polyethylene (LDPE and HDPE) and polypropylene (PP). J Hazard Mater. 2007;149:536–42. https://doi.org/10.1016/j.jhazmat.2007.06.076.

    Article  CAS  PubMed  Google Scholar 

  40. Naviroj P, Treacy J, Urffer C. Chemical Recycling of Plastics by Dissolution. 2019.

  41. Wong SL, Ngadi N, Abdullah T. a. T. study on dissolution of low density polyethylene (LDPE). Appl Mech Mater. 2015;695:170–3. https://doi.org/10.4028/www.scientific.net/AMM.695.170.

    Article  Google Scholar 

  42. Armbruster DA, Pry T. Limit of blank, limit of detection and limit of quantitation. Clin Biochem Rev. 2008;29:S49-52.

    PubMed  PubMed Central  Google Scholar 

  43. Shrivastava A, Gupta VB. Methods for the determination of limit of detection and limit of quantitation of the Analytical methods. Chron Young Sci. 2011;2:21–5.

    Article  Google Scholar 

  44. Sun S, Jin M, Zhou X, Ni J, Jin X, Liu H, Wang Y. The application of quantitative 1H-NMR for the determination of Orlistat in tablets. Molecules. 2017;22: 1517. https://doi.org/10.3390/molecules22091517.

    Article  CAS  PubMed  PubMed Central  Google Scholar 

  45. Brander SM, Renick VC, Foley MM, Steele C, Woo M, Lusher A, Carr S, Helm P, Box C, Cherniak S, et al. Sampling and quality assurance and quality control: a guide for scientists investigating the occurrence of microplastics across matrices. Appl Spectrosc. 2020;74:1099–125. https://doi.org/10.1177/0003702820945713.

    Article  CAS  PubMed  Google Scholar 

  46. Prata JC, Da Costa JP, Duarte AC, Rocha-Santos T. Methods for sampling and detection of microplastics in water and sediment: a critical review. TrAC Trends Anal Chem. 2019;110:150–9. https://doi.org/10.1016/j.trac.2018.10.029.

    Article  CAS  Google Scholar 

  47. Tamis JE, Koelmans AA, Dröge R, Kaag NHBM, Keur MC, Tromp PC, Jongbloed RH. Environmental risks of car tire microplastic particles and other road runoff pollutants. Microplastics Nanoplastics. 2021;1:1. https://doi.org/10.1186/s43591-021-00008-w.

    Article  Google Scholar 

  48. Luo Z, Zhou X, Su Y, Wang H, Yu R, Zhou S, Xu EG, Xing B. Environmental occurrence, fate, impact, and potential solution of tire microplastics: similarities and differences with tire wear particles. Sci Total Environ. 2021;795:148902. https://doi.org/10.1016/j.scitotenv.2021.148902.

    Article  CAS  PubMed  Google Scholar 

  49. Hamad K, Kaseem M, Yang HW, Deri F, Ko YG. Properties and medical applications of polylactic acid: a review. Express Polym Lett. 2015;9:435–55. https://doi.org/10.3144/expresspolymlett.2015.42.

    Article  CAS  Google Scholar 

  50. Taib N-AAB, Rahman MR, Huda D, Kuok KK, Hamdan S, Bakri MKB, Julaihi MRMB, Khan AA. Review on Poly Lactic Acid (PLA) as a biodegradable polymer. Polym Bull. 2023;80:1179–213. https://doi.org/10.1007/s00289-022-04160-y.

    Article  CAS  Google Scholar 

  51. Auras RA, Singh SP, Singh JJ. Evaluation of oriented poly(Lactide) Polymers vs. existing PET and Oriented PS for Fresh Food Service Containers. Packag Technol Sci. 2005;18:207–16. https://doi.org/10.1002/pts.692.

    Article  CAS  Google Scholar 

  52. Singla M, Díaz J, Broto-Puig F, Borrós S. Sorption and release process of Polybrominated Diphenyl Ethers (PBDEs) from different composition microplastics in aqueous medium: solubility parameter approach. Environ Pollut. 2020;262: 114377. https://doi.org/10.1016/j.envpol.2020.114377.

    Article  CAS  PubMed  Google Scholar 

  53. García MT, Gracia I, Duque G, Lucas A, Rodríguez JF. Study of the solubility and stability of polystyrene wastes in a dissolution recycling process. Waste Manag. 2009;29:1814–8. https://doi.org/10.1016/j.wasman.2009.01.001.

    Article  CAS  PubMed  Google Scholar 

  54. Haba Y, Balazs YS, Carmiel O, Katz I, Narkis M, Schmidt ANMR. Investigations of Reactively Extruded PVC/PMMA and PVC/PS blends. Polym Adv Technol. 2007;18:756–65. https://doi.org/10.1002/pat.958.

    Article  CAS  Google Scholar 

  55. Espartero JL, Rashkov I, Li SM, Manolova N, Vert MNMR. Analysis of low molecular weight poly (Lactic Acid)s. Macromolecules. 1996;29:3535–9. https://doi.org/10.1021/ma950529u.

    Article  CAS  Google Scholar 

  56. Fulmer GR, Miller AJM, Sherden NH, Gottlieb HE, Nudelman A, Stoltz BM, Bercaw JE, Goldberg KI. NMR chemical shifts of trace impurities: common laboratory solvents, organics, and gases in Deuterated solvents relevant to the Organometallic chemist. Organometallics. 2010;29:2176–9. https://doi.org/10.1021/om100106e.

    Article  CAS  Google Scholar 

  57. Wackerly JW, Dunne JF. Synthesis of polystyrene and molecular weight determination by 1 H NMR end-group analysis. J Chem Educ. 2017;94:1790–3. https://doi.org/10.1021/acs.jchemed.6b00814.

    Article  CAS  Google Scholar 

  58. Tanaka Y, Sato H. Determination of sequence distribution in polyisoprene by 1 H-NMR spectroscopy. J Polym Sci Polym Lett Ed. 1978;16:473–6. https://doi.org/10.1002/pol.1978.130160907.

    Article  CAS  Google Scholar 

  59. Tang Q, Gao K. Structure analysis of olyether-based thermoplastic polyurethane elastomers by FTIR, 1 H NMR and 13 C NMR. Int J Polym Anal Charact. 2017;22:569–74. https://doi.org/10.1080/1023666X.2017.1312754.

    Article  CAS  Google Scholar 

  60. Cerceau CI, Barbosa LCA, Alvarenga ES, Ferreira AG, Thomasi SS. A validated 1H NMR method for quantitative analysis of α-Bisabolol in essential oils of Eremanthus Erythropappus. Talanta. 2016;161:71–9. https://doi.org/10.1016/j.talanta.2016.08.032.

    Article  CAS  PubMed  Google Scholar 

  61. de Myttenaere A, Golden B, Le Grand B, Rossi F. Mean absolute percentage error for regression models. Neurocomputing. 2016;192:38–48. https://doi.org/10.1016/j.neucom.2015.12.114.

    Article  Google Scholar 

  62. Huber PJ. Robust Estimation of a Location Parameter. In Breakthroughs in Statistics: Methodology and Distribution; Kotz, S., Johnson, N.L., Eds.; Springer Series in Statistics; Springer: New York, NY, 1992; pp. 492–518 ISBN 978-1-4612-4380-9.

  63. Dalisay DS, Molinski TF. NMR quantitation of natural products at the nanomole scale. J Nat Prod. 2009;72:739–44. https://doi.org/10.1021/np900009b.

    Article  CAS  PubMed  PubMed Central  Google Scholar 

  64. Zia KM, Bhatti HN, Ahmad Bhatti I. Methods for polyurethane and polyurethane composites, recycling and recovery: a review. React Funct Polym. 2007;67:675–92. https://doi.org/10.1016/j.reactfunctpolym.2007.05.004.

    Article  CAS  Google Scholar 

  65. Malz F, Jancke H. Validation of quantitative NMR. J Pharm Biomed Anal. 2005;38:813–23. https://doi.org/10.1016/j.jpba.2005.01.043.

    Article  CAS  PubMed  Google Scholar 

  66. Barding GA, Salditos R, Larive CK. Quantitative NMR for bioanalysis and metabolomics. Anal Bioanal Chem. 2012;404:1165–79. https://doi.org/10.1007/s00216-012-6188-z.

    Article  CAS  PubMed  Google Scholar 

  67. Imhof HK, Schmid J, Niessner R, Ivleva NP, Laforsch CA, Novel. Highly efficient method for the separation and quantification of plastic particles in sediments of aquatic environments. Limnol Oceanogr Methods. 2012;10:524–37. https://doi.org/10.4319/lom.2012.10.524.

    Article  CAS  Google Scholar 

  68. Haave M, Lorenz C, Primpke S, Gerdts G. Different stories told by small and large microplastics in sediment - first report of microplastic concentrations in an urban recipient in Norway. Mar Pollut Bull. 2019;141:501–13. https://doi.org/10.1016/j.marpolbul.2019.02.015.

    Article  CAS  PubMed  Google Scholar 

  69. Simon M, van Alst N, Vollertsen J. Quantification of microplastic mass and removal rates at wastewater treatment plants applying Focal Plane Array (FPA)-based Fourier Transform Infrared (FT-IR) imaging. Water Res. 2018;142:1–9. https://doi.org/10.1016/j.watres.2018.05.019.

    Article  CAS  PubMed  Google Scholar 

  70. Haave M, Henriksen T. Kartlegging av mikroplastkilder i urbant miljø fra land til sjø - kilder, mengder og spredning. NORCE nor Res Cent. 2022.

  71. Büks F, Kaupenjohann M. Global concentrations of microplastics in soils – a review. SOIL. 2020;6:649–62. https://doi.org/10.5194/soil-6-649-2020.

    Article  Google Scholar 

  72. Lusher AL, Hurley R, Arp HPH, Booth AM, Bråte ILN, Gabrielsen GW, Gomiero A, Gomes T, Grøsvik BE, Green N, et al. Moving forward in microplastic research: a norwegian perspective. Environ Int. 2021;157: 106794. https://doi.org/10.1016/j.envint.2021.106794.

    Article  CAS  PubMed  Google Scholar 

  73. van Mourik LM, Crum S, Martinez-Frances E, van Bavel B, Leslie HA, de Boer J, Cofino WP. Results of WEPAL-QUASIMEME/NORMANs first global interlaboratory study on microplastics reveal urgent need for harmonization. Sci Total Environ. 2021;772:145071. https://doi.org/10.1016/j.scitotenv.2021.145071.

    Article  CAS  PubMed  Google Scholar 

  74. Lorenz C, Roscher L, Meyer MS, Hildebrandt L, Prume J, Löder MGJ, Primpke S, Gerdts G. Spatial distribution of microplastics in sediments and surface waters of the southern north sea. Environ Pollut. 2019;252:1719–29. https://doi.org/10.1016/j.envpol.2019.06.093.

    Article  CAS  PubMed  Google Scholar 

  75. Mintenig SM, Int-Veen I, Löder MGJ, Primpke S, Gerdts G. Identification of microplastic in effluents of waste water treatment plants using focal plane array-based micro-fourier-transform infrared imaging. Water Res. 2017;108:365–72. https://doi.org/10.1016/j.watres.2016.11.015.

    Article  CAS  PubMed  Google Scholar 

  76. Bergmann M, Wirzberger V, Krumpen T, Lorenz C, Primpke S, Tekman MB, Gerdts G. High quantities of microplastic in arctic deep-sea sediments from the HAUSGARTEN bservatory. Environ Sci Technol. 2017;51:11000–10. https://doi.org/10.1021/acs.est.7b03331.

    Article  CAS  PubMed  Google Scholar 

Download references

Acknowledgements

Not applicable.

Funding

Open access funding provided by University of Bergen. This research was financially supported by the Research Council of Norway (project 320456) and the National Natural Science foundation of China (Grant No. 32061133005).

Author information

Authors and Affiliations

Authors

Contributions

JS designed the study, acquired, and analysed the data; MH and JS contributed to validation of method and data;  JS, MH, JU and WW contributed to the drafting and revising the study; WW contributed to funding acquisition and management.

Corresponding author

Correspondence to Wei Wang.

Ethics declarations

Ethics approval and consent to participate

Not applicable.

Consent for publication

All authors have read and approved the manuscript and agree with its submission.

Competing interests

The authors declare no competing interests.

Additional information

Publisher’s note

Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.

Supplementary Information

Rights and permissions

Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/.

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Schmidt, J., Haave, M., Underhaug, J. et al. Unlocking the potential of NMR spectroscopy for precise and efficient quantification of microplastics. Micropl.&Nanopl. 4, 17 (2024). https://doi.org/10.1186/s43591-024-00095-5

Download citation

  • Received:

  • Accepted:

  • Published:

  • DOI: https://doi.org/10.1186/s43591-024-00095-5

Keywords